Typical Application Scenarios
SLS-100WF can provide high uniformity and high stability of output luminance. It is used for flat field correction test of large field of view cameras. The field of view of measurement applications can reach 230°. SLS-100WF adopts precise constant current control and built-in high-precision monitoring probe, which can realize luminance adjustment with wide dynamic range and high stability. It is suitable for flat field correction of AR/VR cameras, security cameras, mobile phone cameras and other equipment. and dynamic range testing.
Main Characteristics
1.Adjustment range of spherical center illumination: 0-5000lx.
2.Color temperature 5000K,Color temperature can be adjusted dynamically adjusted
3.Built-in high precision illuminance / luminance sensor, which can be traced to NIM or NIST
4.Precision constant current power supply, high output stability
5.Software customization: secondary development kits can be provided